The other reactors can have "dumb" output inserters that remove empty fuel cells immediately. This will synchronize fuel insertion to maximize the reactor neighbour heat bonus. If you are using multiple reactors you should only wire one output inserter to one steam tank, and then connect all input inserters to the single output inserter.The "Override stack size" is set to 1, so that it only inserts 1 fuel cell at a time. This is connected to the output inserter and listens for the empty fuel cell signal. Input inserter that put uranium fuel cells into the reactor. If the steam level is low and there are uranium fuel cells available, it removes the empty fuel cells from the reactor and sends an empty fuel cell signal (since "Read hand contents" is checked). This is connected to the storage tank to listen for the steam signal, and to the chests to listen for the uranium fuel cell signal. Output inserter that takes empty fuel cells from the reactor.Chests containing uranium fuel cells for the reactor.You should only read from one storage tank, and it should have pipe connections to all your other steam storage tanks. Storage tank that provides the steam signal.Note: The GUI in the image above has been altered to make sure all important info fits within the image size. This picture shows a setup with 4 reactors, that spend only 1 fuel cell each whenever steam runs low. If a precise count is needed, set the inserter stack size to 1. Thus if that number is negative, it has less than the average in the chest and it enables.ĭue to inserter stack bonus the count is not exact. it calculates how many more than the average it has in its chest. Each inserter gets the amount in the chest it is inserting to and adds the negative average, i.e. The combinator calculates the average number of items in the chests, and makes it negative. Set the enable condition on each inserter to be Everything (red star) Connect each inserter to the box it inserts into with green wire.Connect all inserters to each other and to the output of the combinator using red wire.Connect all chests to each other and to the input of the combinator using red wire.Set the combinator to take Each (yellow star) and divide by the negative number of chests.Goal: Load n chests with approximately the same number of items. This will prevent fluid system deadlocks where you have plenty of one fluid but you are unable to make any of the other. set "heavy oil > light oil" for the heavy oil cracking input pump, set "heavy oil > lubricant" for the lubricant production input pump, and set "light oil > petroleum gas" for the light oil cracking input pump.ĭone! Now all the pumps will move to equalize the fluid levels to each other. For each connected pump set the circuit “enable condition” to " > ", for its respective chemical plant recipe.The resulting circuit network will know about the fluid level in every storage tank and pass this information to every pump. Connect every pump and every fluid tank to a single circuit network of red (or green) wire. Note: Alternatively, the blocking pumps could be added to the chemical plant output pipes, but there is no need to add pumps to both inputs and outputs.
0 Comments
Leave a Reply. |